Posted in

What are the considerations for using an Explosion Proof Wireless AP in a large – scale network?

If you’ve ever spent time in a facility where there’s any risk of explosive atmospheres—think oil refineries, chemical processing plants, grain silos, or offshore drilling platforms—you know that standard wireless network gear is never going to cut it. As someone who’s spent the last decade supplying explosion-proof wireless APs (Access Points) to industrial and hazardous location operators, I’ve lost count of how many project managers come to me after a costly, dangerous mistake: they tried to save a few bucks with a regular AP, and it triggered an ignition, caused an unplanned shutdown, or landed their team in serious regulatory hot water. Explosion Proof Wireless AP

A large-scale network in these environments isn’t just a convenience—it’s critical. It connects process control systems, worker safety devices, and emergency response tools that keep operations running and people alive. But deploying the right gear here isn’t as simple as checking a box for “wireless coverage.” There are dozens of nuanced, often overlooked considerations that go into picking and implementing an explosion-proof (XP) wireless AP at scale. Let’s break down what I walk every customer through, step by step.

First and foremost: hazard classification is non-negotiable, and getting it wrong is a fatal error. Not all hazardous locations are the same, and regulators like the NEC (National Electrical Code) in the U.S., ATEX in the EU, IECEx internationally, split these spaces into different zones, classes, and divisions based on what explosive materials are present, how much of it is there, and how likely it is to leak or release.

For example, a Class I, Division 1 location (or Zone 0, for gas/vapor risks) has a flammable atmosphere present continuously or for long periods under normal operating conditions. A Class I, Division 2 (or Zone 2) only has that atmosphere under abnormal conditions, like a seal failure on a pipe. You can’t put a general XP AP for Division 1 in a Zone 2 space, and vice versa—their internal components, encapsulation methods, and testing ratings are wildly different. At my company, we run into this all the time with customers expanding a refinery: they’ll add a new storage tank farm that’s Zone 1, and their old XP APs for the main processing area (Zone 2) won’t pass muster there. We’ve seen projects delayed for 3+ months because a vendor sold the wrong rated AP, so my team always starts every consultation by asking for their exact hazard zone maps—no assumptions allowed.

Next, enclosure integrity is the backbone of XP APs, and it’s not just about picking a metal box. The XP enclosure’s job is two-fold: first, it contains any explosion that might happen inside the AP, preventing it from igniting the surrounding atmosphere. Second, it keeps the explosive atmosphere out of the AP, so the AP’s internal electronics don’t spark, overheat, or arc and trigger a blast. But for large-scale deployments, the enclosure has to hold up for years, even decades, in harsh industrial conditions.

I’ve seen cheap XP APs made with thin cast aluminum that corrode within 5 years from exposure to hydrogen sulfide in refineries or grain dust in silos. Corrosion creates gaps in the enclosure—what’s called flame paths—that don’t work as designed. The NEC requires flame paths to be machined to exact depths and widths to quench an internal explosion, but a corroded gap ruins that. For large networks, we specify APs with 316L stainless steel enclosures, not just regular aluminum, because it’s resistant to corrosion from almost all common hazardous materials. We also test every batch of our APs for ingress protection (IP) ratings: an IP67 rating means it’s dust-tight and can survive being submerged in 1 meter of water for 30 minutes, which is non-negotiable for outdoor facilities like offshore platforms or rain-exposed tank farms.

Then there’s performance at scale, which is something a lot of vendors overlook when they pitch XP APs. People assume that because an AP is certified for hazardous locations, it’s automatically good enough for a network with hundreds of APs supporting thousands of devices. But industrial networks have unique performance needs. Workers in a refinery might be using wearables that track their location and air quality, process control systems are sending real-time data on pipeline pressure, and drones are being used to inspect pipelines—all of these need reliable, low-latency connectivity that doesn’t drop or lag.

Standard indoor APs use consumer-grade Wi-Fi chips that can only support 15-20 devices at once. But an XP AP in a large grain silo might be supporting 50+ employees with tablets, IoT sensors monitoring grain temperature, and security cameras. We design our XP APs with industrial-grade Wi-Fi 6 or Wi-Fi 6E chips that can handle up to 100 concurrent devices, and we optimize the radio frequency (RF) layout specifically for hazardous environments. RF interference is a huge problem here: chemical plants have thousands of metal pipes, which reflect Wi-Fi signals like crazy, and other industrial equipment runs on the same frequency bands. At my company, we work with network integrators to do a full site survey before deploying APs, mapping out dead zones, interference sources, and optimal placement. For example, in a tank farm with 100-foot-tall storage tanks, placing an AP 20 feet above ground on a pole avoids the signal blocking from the tank walls. We also use beamforming technology that targets devices instead of broadcasting in all directions, which cuts down on interference and saves power—critical for remote facilities where APs might be running on solar or backup power.

Power supply is another make-or-break consideration for large-scale XP networks. Industrial hazardous locations often have unreliable power, or require redundant power to avoid downtime that could be catastrophic. Standard APs plug into regular wall power, but XP APs need to be powered in a way that doesn’t create a spark. PoE (Power over Ethernet) is the most common method, but not all PoE is created equal. Low-power PoE (802.3af) can only supply 15 watts, which is fine for small indoor APs, but our XP APs for outdoor sites need 30 watts (802.3at) or even 60 watts (802.3bt) to power extra radios for better coverage and IoT sensors.

We also strongly recommend redundant power sources: if one line goes down, the AP doesn’t lose connectivity. Many of our customers in remote areas add backup batteries to each AP, or connect them to a separate UPS (Uninterruptible Power Supply) that’s certified for hazardous locations. One of our clients in the North Sea had a power outage that knocked out their regular network, but their XP APs with backup battery stayed online, letting their team shut down wells safely instead of risking a leak. I can’t stress enough that for large networks, you can’t have a single point of failure in power—every AP needs a reliable, spark-safe power source that’s rated for their hazard zone.

Regulatory compliance and documentation might sound like administrative busywork, but it’s the difference between a project that gets approved and one that gets shut down. Industrial facilities have to pass regular audits from OSHA, EPA, or international safety bodies, and every piece of equipment in a hazardous location has to have paper trail proving it meets the exact certification standards.

I’ve seen integrators buy uncertified “XP-rated” APs from overseas vendors that don’t have proper testing from a notified body like UL, CSA, or TÜV. These APs might look right, but they haven’t passed the rigorous testing required to ensure they don’t ignite an explosion. For large-scale deployments, we provide a full set of documentation for every AP: certification reports, installation manuals, maintenance schedules, and even a hazard zone compatibility chart. We also work with compliance teams to make sure the network design meets all local codes. One of our largest customers, a petrochemical plant with 250+ XP APs, told us that our documentation cut their audit time by 50% because every piece of gear was fully traceable.

Maintenance and lifecycle support for a large XP network is something no one thinks about when they’re first deploying, but it’s the biggest long-term cost factor. Regular APs can be swapped out in 10 minutes with a screwdriver, but XP APs require special tools and certified technicians to open and service them—because opening the wrong part at the wrong time could be dangerous.

That’s why we design our APs for easy, safe maintenance: all internal components are locked with XP-rated screws that only can only be opened with a specific tool, and we provide training for our customers’ maintenance teams on how to inspect the flame paths, check for corrosion, and replace parts without voiding the certification. For large networks, we also offer remote monitoring tools that let us check the health of every AP from our office. If an AP’s signal drops or its enclosure integrity is compromised by weather or corrosion, we can alert the team before it becomes a problem. We also offer a 10-year warranty on all our XP APs, because we know that in hazardous locations, downtime isn’t an option—you need gear that lasts.

Security is the final, often overlooked consideration for large-scale XP networks. Industrial control systems and worker safety data are high-value targets for cyberattacks, and if a hacker takes over a wireless AP in a hazardous location, they could tamper with process controls or disable worker safety tools. XP APs don’t have to be insecure by default, but many cheap models for hazardous locations skimp on security features to keep costs low.

All of our XP APs come with enterprise-grade security: WPA3 encryption, 802.1X authentication, and support for network segmentation that separates worker devices from process control devices. We also integrate our APs with zero-trust security platforms, so every device on the network has to be verified before it connects. For example, a worker’s tablet can connect to the network, but it can only access their assigned safety tools, not the process control servers. That way, if a device is compromised, it can’t spread through the entire network and cause a safety incident.

At the end of the day, deploying a large-scale explosion-proof wireless AP network isn’t just about picking a certified device—it’s about understanding your facility’s specific hazards, designing a reliable RF layout, ensuring proper power, staying compliant with regulations, planning for long-term maintenance, and securing every part of the network. As an XP wireless AP supplier, I’ve worked with dozens of clients to avoid the mistakes that lead to dangerous failures, and I’m always happy to walk through these considerations with new teams. If you’re planning an expansion or a new network in a hazardous location, reach out to our team to start a conversation about your specific needs.

WiFi AP References

  1. National Fire Protection Association. (2023). NFPA 70: National Electrical Code. Quincy, MA: National Fire Protection Association.
  2. International Electrotechnical Commission. (2021). IEC 60079: Explosive atmospheres. Geneva, Switzerland: International Electrotechnical Commission.
  3. Occupational Safety and Health Administration. (2022). Hazardous Locations: Electrical Safety. Washington, D.C.: U.S. Department of Labor.
  4. Industrial Communication Technology Foundation. (2021). Wireless Technologies for Industrial Automation and Control. Austin, TX: Industrial Communication Technology Foundation.
  5. Underwriters Laboratories. (2020). UL 60079-0: Explosive atmospheres – Part 0: Equipment – General requirements. Northbrook, IL: Underwriters Laboratories Inc.

Jinan Bodaxun Communication Technology Co., Ltd.
With abundant experience, we are one of the most professional explosion proof wireless ap manufacturers and suppliers in China. Please rest assured to buy high quality explosion proof wireless ap for sale here from our factory. For price consultation, contact us.
Address: 4-501, Future Smart Manufacturing Center, China Computing Valley, Liandong U Valley, High-tech Zone, Jinan City, Shandong Province
E-mail: lmj@bodacomwlan.com